切换至 "中华医学电子期刊资源库"

中华危重症医学杂志(电子版) ›› 2021, Vol. 14 ›› Issue (05) : 420 -424. doi: 10.3877/cma.j.issn.1674-6880.2021.05.014

综述

脉搏指示连续心排出量在危重症患者中应用的研究进展
何玮1, 孙立群1,()   
  1. 1. 210000 南京,南京医科大学第二附属医院重症医学科
  • 收稿日期:2020-09-28 出版日期:2021-10-31
  • 通信作者: 孙立群
  • 基金资助:
    江苏省普通高校自然科学研究计划项目(19KJB320001); 南京医科大学第二附属医院"789"卓越人才培养项目(789ZYRC202070317)
  • Received:2020-09-28 Published:2021-10-31
引用本文:

何玮, 孙立群. 脉搏指示连续心排出量在危重症患者中应用的研究进展[J]. 中华危重症医学杂志(电子版), 2021, 14(05): 420-424.

1
阳建国,汪一棋,赵朝辉,等.脉搏指数连续心输出量技术在重型颅脑损伤患者中的应用分析[J/CD].中华危重症医学杂志(电子版)20169(1):44-46.
2
Riviello ED, Kiviri W, Twagirumugabe T, et al. Hospital incidence and outcomes of the acute respiratory distress syndrome using the Kigali modification of the Berlin definition[J]. Am J Respir Crit Care Med, 2016, 193 (1): 52-59.
3
Zhang Z, Ni H, Qian Z. Effectiveness of treatment based on PiCCO parameters in critically ill patients with septic shock and/or acute respiratory distress syndrome: a randomized controlled trial[J]. Intensive Care Med, 2015, 41 (3): 444-451.
4
Zhong Y, Wang J, Shi F, et al. ICU management based on PiCCO parameters reduces duration of mechanical ventilation and ICU length of stay in patients with severe thoracic trauma and acute respiratory distress syndrome[J]. Ann Intensive Care, 2016, 6 (1): 113.
5
Huber W, Findeisen M, Lahmer T, et al. Prediction of outcome in patients with ARDS: a prospective cohort study comparing ARDS-definitions and other ARDS-associated parameters, ratios and scores at intubation and over time[J]. PLoS One, 2020, 15 (5): e0232720.
6
Pathil A, Stremmel W, Schwenger V, et al. The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock: an observational study[J]. Eur J Anaesthesiol, 2013, 30 (1): 16-20.
7
Huber W, Fuchs S, Minning A, et al. Transpulmonary thermodilution (TPTD) before, during and after sustained low efficiency dialysis (SLED). A prospective study on feasibility of TPTD and prediction of successful fluid removal[J]. PLoS One, 2016, 11 (4): e0153430.
8
Geith S, Stecher L, Rabe C, et al. Sustained low efficiency dialysis should not be interrupted for performing transpulmonary thermodilution measurements[J]. Ann Intensive Care, 2018, 8 (1): 113.
9
Heise D, Faulstich M, Morer O, et al. Influence of continuous renal replacement therapy on cardiac output measurement using thermodilution techniques[J]. Minerva Anestesiol, 2012, 78 (3): 315-321.
10
Cecconi M, Evans L, Levy M, et al. Sepsis and septic shock[J]. Lancet, 2018, 392 (10141): 75-87.
11
Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock[J]. N Engl J Med, 2001, 345 (19): 1368-1377.
12
Liu X, Ji W, Wang J, et al. Application strategy of PiCCO in septic shock patients[J]. Exp Ther Med, 2016, 11 (4): 1335-1339.
13
Zhang W, Danzeng Q, Feng X, et al. Sequential organ failure assessment predicts outcomes of pulse indicator contour continuous cardiac output-directed goal therapy: a prospective study[J]. Medicine (Baltimore), 2017, 96 (39): e8111.
14
van Diepen S, Katz JN, Albert NM, et al. Contemporary management of cardiogenic shock: a scientific statement from the American Heart Association[J]. Circulation, 2017, 136 (16): e232-e268.
15
Zhang YB, Zhang ZZ, Li JX, et al. Application of pulse index continuous cardiac output system in elderly patients with acute myocardial infarction complicated by cardiogenic shock: a prospective randomized study[J]. World J Clin Cases, 2019, 7 (11): 1291-1301.
16
Bittner EA, Shank E, Woodson L, et al. Acute and perioperative care of the burn-injured patient[J]. Anesthesiology, 2015, 122 (2): 448-464.
17
Branski LK, Herndon DN, Byrd JF, et al. Transpulmonary thermodilution for hemodynamic measurements in severely burned children[J]. Crit Care, 2011, 15 (2): R118.
18
Jeschke MG, Gauglitz GG, Kulp GA, et al. Long-term persistance of the pathophysiologic response to severe burn injury[J]. PLoS One, 2011, 6 (7): e21245.
19
Gong C, Zhang F, Li L, et al. The variation of hemodynamic parameters through PiCCO in the early stage after severe burns[J]. J Burn Care Res, 2017, 38 (6): e966-e972.
20
Wurzer P, Branski LK, Jeschke MG, et al. Transpulmonary thermodilution versus transthoracic echocardiography for cardiac output measurements in severely burned children[J]. Shock, 2016, 46 (3): 249-253.
21
Briel M, Meade M, Mercat A, et al. Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: systematic review and meta-analysis[J]. JAMA, 2010, 303 (9): 865-873.
22
Zhao Z, Jiang L, Xi X, et al. Prognostic value of extravascular lung water assessed with lung ultrasound score by chest sonography in patients with acute respiratory distress syndrome[J]. BMC Pulm Med, 2015 (15): 98.
23
Horster S, Stemmler HJ, Strecker N, et al. Cardiac output measurements in septic patients: comparing the accuracy of USCOM to PiCCO[J]. Crit Care Res Pract, 2012 (2012): 270631.
24
Button D, Weibel L, Reuthebuch O, et al. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery[J]. Br J Anaesth, 2007, 99 (3): 329-336.
25
McGee WT, Horswell JL, Calderon J, et al. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial[J]. Crit Care, 2007, 11 (5): R105.
26
Sander M, Spies CD, Grubitzsch H, et al. Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements[J]. Crit Care, 2006, 10 (6): R164.
27
Hofer CK, Button D, Weibel L, et al. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients[J]. J Cardiothorac Vasc Anesth, 2010, 24 (2): 257-264.
28
Ji F, Li J, Fleming N, et al. Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine[J]. J Clin Monit Comput, 2015, 29 (4): 467-473.
29
Suehiro K, Tanaka K, Mikawa M, et al. Improved performance of the fourth-generation FloTrac/Vigileo system for tracking cardiac output changes[J]. J Cardiothorac Vasc Anesth, 2015, 29 (3): 656-662.
30
Hattori K, Maeda T, Masubuchi T, et al. Accuracy and trending ability of the fourth-generation FloTrac/Vigileo system in patients with low cardiac index[J]. J Cardiothorac Vasc Anesth, 2017, 31 (1): 99-104.
31
Eisenried A, Klarwein R, Ihmsen H, et al. Accuracy and trending ability of the fourth-generation FloTrac/EV1000 system in patients with severe aortic valve stenosis before and after surgical valve replacement[J]. J Cardiothorac Vasc Anesth, 2019, 33 (5): 1230-1236.
32
Khwannimit B, Jomsuriya R. Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients[J]. Turk J Med Sci, 2020, 50 (4): 860-869.
33
Ameloot K, Van De Vijver K, Broch O, et al. Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients[J]. ScientificWorldJournal, 2013 (2013): 519080.
34
张磊,阳建国,钟兴明,等.脉搏指数连续心排血量监测在重症脑出血患者经控制性开颅血肿清除术治疗中的价值[J/CD].中华危重症医学杂志(电子版)201912(5):338-342.
No related articles found!
阅读次数
全文


摘要